Business scope

Halogen (F.Cl.Br.I)

Time:2020-09-18 16:09:12CTR:

Introduction to testing


Halogen testing is mainly applied to the content of flame retardants added in the production process of electronic and electrical products, plastic accessories, PCB boards, film polymers, resins, inks, etc., by measuring the halogen content of the flame retardant. Determine whether it meets the requirements of EU IEC61249-2-21: 2003.

  

Test standard


EN 14582:2007; JY/T020:1996.

 

Standard limit


 Chlorine (Cl)≤900ppm,

Bromo(Br) ≤900ppm,,

Chlorine (Cl) + Bromine (Br) ≤1500ppm.

 

Test Ability


Fluorine (F), chlorine (Cl), bromine (Br), iodine (I), method detection limit (MDL): 50ppm


Test requirements


Customers need to provide solid (including powder) samples of more than 5 g or liquid samples of more than 10 mL. For viscous samples, it is necessary to confirm whether the drying test is required. For non-single material samples, customers need to confirm whether they are mixed. Test or specify the test site.


Test cycle


General test cycle 4WD
Expedited test cycle 3WD
Urgent test cycle 2WD


Test instrument


Thermofei (formerly Di’an) IC-900 ion chromatograph, Milli-Q Direct water purifier, vacuum pump suction filter, oxygen bomb (including absorption bottle), Inflatable device, ignition device.